EXAIR CABINET COOLER PDF

EXAIR CABINET COOLER PDF

EXAIR Cabinet Coolers incorporate a vortex tube to produce cold air from compressed air – with no moving parts. The compact Cabinet Cooler can be installed. What is an EXAIR Cabinet Cooler System? A low cost, reliable way to cool and purge electronic control panels. EXAIR Cabinet Coolers incorporate a vortex tube . EXAIR Cabinet Coolers, Cooling electronic control, Picking the right Cabinet Cooler, NEMA 4, NEMA 12, NEMA 4x, buy now at Eputec.

Author: Najind Zurisar
Country: Mongolia
Language: English (Spanish)
Genre: Business
Published (Last): 4 March 2006
Pages: 440
PDF File Size: 16.73 Mb
ePub File Size: 13.52 Mb
ISBN: 442-1-41141-497-1
Downloads: 95479
Price: Free* [*Free Regsitration Required]
Uploader: Kagarisar

The Heavy Duty Dry Vac has been engineered to vacuum more dry materials in less time with less wear. Only the cool, clean, dry air enters the cabinet — no dirty, hot humid outside air is ever allowed into the cabinet! The Sanitary Flange Line Vac fits within your current sanitary flange piping system and converts it into a conveyor for waste, parts, and bulk materials. Email to a Friend. Quiet, efficient Air Amplifiers will create output flows up to 25 times their consumption rate.

EXAIR Cabinet Cooler – Cabinet Cooling – Picking the right Cabinet Cooler

Compressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. The Chip Trapper vacuums the coolant or liquid that is filled with debris and traps all the solids in a reusable filter bag.

The timing control permits easy tuning to the application requirements while providing flexibility in sensing distance.

A small amount of compressed air is throttled through an internal ring nozzle above sonic velocity. Heat build up on dry machining operations reduces tool life and machining dxair. This valve closes and seals when the cooler is not operating to maintain the integrity of a NEMA 4X enclosure.

Operation is quiet and there are no moving parts to wear out. Internal mix nozzles can be used on liquids with a viscosity up to cP. Cooling in high temperature environments High Temperatures are no problem for EXAIR Cabinet Coolers Due to their nature of operation, an air-to-air heat exchanger must have an ambient temperature which is lower than the desired internal temperature of the enclosure. Chip Shields are durable polycarbonate shields that protects operators from flying debris often associated with blowing chips off machined parts.

  ENSIKLOPEDI KERIS BAMBANG HARSRINUKSMO PDF

With force values from 2 oz. Vortex Tubes can produce:. An internal float automatically activates the drain when full. Both the vacuum and discharge ends of the Air Amplifier can be ducted, making them ideal for drawing fresh air from another location, or moving smoke and fumes away.

The Model Digital Static Fabinet allows easy one-hand static measurements. A proven way to reduce downtime and increase productivity on a variety of operations involving small parts where heat is a problem. Check out this video to see how simple Cabinet Coolers are to install. Some applications require extremely high force with extensive reach and these nozzles are the solution by offering force values from 1 lb g through 23 lbs Available to improve applications with flow up to SCFM.

The Gen4 Ion Air Jet is the ideal way to remove static and dust from small parts prior to shrink wrapping, packaging, printing, painting or finishing. The hardened alloy construction helps prevent premature wear that could occur with ordinary aluminum or stainless steel Line Vacs. Type or Stainless Steel. Gen4 Ionizing Bars are ideal for relatively flat materials, where the bar can coolfr mounted close to the product surface.

Cabinet Cooler Systems can be configured to run in a Continuous Operation or with Thermostat control.

The controller has easy to use buttons to raise or lower the desired cabinet temperature set-point. S ystems for continuous operation include a Cabinet Cooler, distribution kit and filter.

It maximizes ionized airflow while minimizing compressed air consumption. Chip Shields are also great for keeping coolant from spreading everywhere during drying operations. The durable cast aluminum body is suited for rugged industrial use and includes a convenient hanger hook for easy storage. You are commenting using your Twitter account. But, when these filters become clogged, access to ambient temperatures are reduced, and cooling capacity of the air-to-air unit reduces as well.

  FUNDAMENTOS DE FISIOLOGIA DE LA CONDUCTA CARLSON PDF

It eliminates the costs associated with the purchase and disposal of cutting fluids and worker related health problems from breathing airborne coolants or slipping on wet floors. In most cases, the highest voltage reading will indicate the source of the static problem. Chip Shields are also great for keeping coolant from spreading everywhere during drying operations. The laminar sheet of air sweeps surfaces clean of static, particulate, dust and dirt.

Model 4315 NEMA 12 1,000 Btu/hr Cabinet Cooler w Therm

The High Lift Chip Trapper has the extra power you need to move liquids from below grade work areas, sumps or tanks. EXAIR engineered Air Nozzles and Jets produce outlet flows up to 25 times compressed air consumption using a small amount of compressed air as fxair power source. Hearing loss induced by high noise in the workplace is a common problem.

Complete with a 20′ hose it can also reach farther. You can also choose some of our most popular combinations already combined for your convenience. Chip Shields are durable polycarbonate shields that protects operators from flying debris often associated with blowing chips off machined parts. The EFC combines a photoelectric sensor with a timing control that limits compressed air use by turning it off when no part is present.

The material flow rate is easily controlled with a pressure regulator. Thermostat control is the most efficient way to operate a Cabinet Cooler. Non-Hazardous Purge — ideal for dirty areas where contaminants might normally pass through small holes or conduits. Vacuum Cups and Accessories. Siphon fed nozzles require no liquid pressure and can be used with gravity fed liquids or lift liquids from a siphon height as much as 36 inches 91cm.

A low cost, reliable way to cool and purge electronic control panels, the compact Cabinet Cooler can be installed in minutes through a standard electrical knockout. Fill in your details below or click an icon to log in: