The Emotron M20 offers reliable, repeatable results for monitoring and protecting machines and processes against abnormal conditions. The M20 reduces. Emotron M20 shaft power monitor helps you save time and money. It protects your pumps and other equipment against damage and detects process inefficiency. The M20 provides complete flexibility in terms of the type 1 Emotron M20 and current transformer (CT), both for mounting on standard DIN rail 35mm. Fig.

Author: Dotaur Fauzilkree
Country: Zimbabwe
Language: English (Spanish)
Genre: Education
Published (Last): 18 May 2014
Pages: 297
PDF File Size: 8.26 Mb
ePub File Size: 5.44 Mb
ISBN: 947-9-91196-885-1
Downloads: 29727
Price: Free* [*Free Regsitration Required]
Uploader: Dalrajas

Preventive maintenance instead of repairing or replacing damaged equipment saves time and money.

The result is reduced maintenance and installation costs, extended equipment lifetime and increased reliability. Using the motor as a sensor also reduces installation costs. Using the motor as a sensor eliminates the need for external sensors and extra cabling, and no holes need to be made in pipes.

Emotron M20 Shaft Power Monitor

A unique technique to calculate shaft power results in an accurate and reliable supervision across the whole load range. The result is an accurate and linear motor load value across the emoyron load range.

A special feature offers high accuracy also in the event of very small load variations. The analogue output signal can be scaled to the desired shaft power range and used as an input to controllers.

The Emotron M20 shaft power monitor protects your pumps and other equipment against damage and downtime.

Mm20 — Pre-alarm, alarm and stop before any machine over or under load damage occurs. The shaft power output is indicated on the monitor display in kW or hp, or as a percentage of rated power. Early warnings allow you to take preventive action. Reliable and cost-efficient monitoring The Emotron M20 shaft power monitor protects your pumps and other equipment against damage and downtime.

  EA DE QUEIROZ A CIDADE E AS SERRAS PDF

An analogue current output signal can be j20 to scale the machine load to the actual working range.

Emotron – M20 – FCR Motion

Alarm functions can be set within three seconds at just the push of a key. Enter your settings in three seconds The Emotron M20 uses an Auto set feature that allows four protection set points to be established in just three seconds. Low-cost installation and zero maintenance Using the motor as a sensor eliminates the need for external sensors and extra cabling, and no holes need to be made in pipes.

Early warnings allow for preventive action, thus reducing maintenance costs and increasing reliability. The result is increased reliability and reduced emorton, installation and maintenance costs. Technical data The Emotron M20 shaft power monitor offers advanced multi-function monitoring thanks to two output relays, an analogue output and a display for load indication and parameter settings. The shaft power monitor offers reliable insurance against process failure and its costly consequences.

By pressing Auto set during normal operation, the warning and stop levels are calculated automatically on the basis of the actual motor load measured. Request a Call Back Need some help? Is it a question of hours, days or weeks at your plant? m0

By immediately initiating a warning or stopping the process, the monitor minimizes production downtime, prevents equipment damage and eliminates unnecessary wear. Contact us Contact us. Unique features include measuring shaft power output and using the motor as a sensor. The Emotron M20 shaft power monitor offers advanced multi-function monitoring thanks to two output relays, an analogue output and a display for load indication and parameter settings.

  HALLITE 605 PDF

Emotron M20

Details Unique shaft power monitoring The Emotron M20 immediately detects over- and underload due to, for example, a pump running dry or a crusher jamming. The signal can be used as an input to indicating instruments, controllers or PLCs.

By submiting your details you agree to the terms of our privacy policy. The Emotron M20 uses an Auto set feature that allows four protection set points emotorn be established in just three seconds.

Both current measurement and phase angle emohron used in order to calculate an accurate load value for high as well as for low load levels. Technical Data The Emotron M20 shaft power monitor offers advanced multi-function monitoring thanks to two output relays, an emotroon output and a display for load indication and parameter settings.

Payback time is short, in many cases negligible considering the cost of one single production stop. Manuals Emotron M20, addendum Emotron M20, instruction manual. We are here to assist you! The Emotron M20 shaft power monitor helps you save time and money. High accuracy with scalable output signal A special feature offers high accuracy also in the event of very small load variations.